Solid Core XLPE Power Cable/XLPE Steel Tape Armoured Power Cable

US$0.10 - 99.90 500 Meters (MOQ)
Production Capacity:
172 Kilometer/Kilometers Per Week
Transport Package:
Wooden or Steel-Wooden Drum
Payment Terms:
L/C, T/T

Far East Cable Co., Ltd.

Jiangsu, China

Last Login Date:

Mar 11, 2017

Business Type:

Manufacturer/Factory, Trading Company

Main Products:

XLPE/PVC Insulated Power Cable, Mining Cable, High&Extra High Voltage Cable, ACSR/AAC/AAAC, Building Wire, Power Cable, Control Cable, Accc, Lshf Cable, Fire Resistant Cable

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
YJV,YJV22,YJV23,YJV32,YJV33,YJV42,YJV43,VV,VLV
Application
Construction, Underground, Power Station
Voltage
Low and Medium Voltage Cable
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Copper
Certification
CCC, CE, Kema
Model
Yjv,Yjv22,Yjv23,Yjv32,Yjv33,Yjv42,Yjv43,VV,Vlv
Brand
Far East Cable
Conductor
Pure 99.99% Copper
Brand Name
Far East Cable
Far East Cable
The Largest Wire & Cable Manufacturing Company
Marketing Ability
Exceeds 20 Billion Yuan
Quality
Good Quality
Price
Competitive Price
Rank
Ranked Firstly in China Continuously for 18 Years
Brand Value
19.869 Billion Yuan
Award
"Famous Trademark of China"
Famous
"China Famous Brand Product"
Trademark
Far East Cable
Specification
CE UL KEMA
Origin
Jiangsu, China
HS Code
8544601300

Product Description

 Specifications
1 IEC, ASTM, DIN, BS standard 
2 ISO,CCC,CB certification 
3 Factory direct sale 



solid core xlpe power cable/xlpe steel tape armoured power cable

Application
PVC insulation electric power cable has excellent electrical properties and chemical stability.With simple structure and easy to use,it is suitable for fixed laying AC 50HZ,rated voltage 1kV and below in transmission and distribution lines.Five-core power cable is needed to adapt to the development of distribution system and safety performance,the neutral wire in low voltage distribution systems with the zero line separating the system to run more stable,and ensure the safety of staff.
The XLPE insulation power cable has excellent hot-mechanical properties,excellent electrical,chemical resistance properties,also has the advantage of simple structure,light weight,not restricted by the difference of level along the route.Now widely used in urban power grid,mines and chemical plants and other places.Cable insulation adopt XLPE,use chemical method to linear molecules PE into solid nerwork structure of XLPE,thus substantially improving the mechanical properties of PE,and maintaining the superior ellectrical performance.
The product is suitable for dynamic line transmission and distribution lines of shielding performance requirements more stringent,especially applies to the rated voltage 0.6/1kV and below frequency inverter control system for power supply or connectiing cables.Frequency conversion cable is actually a shield-type power cable,the difference is that ground wires are divided into third part placed in the three main line between core to uniform electric field and improve levels of electromagnetic radiation of cable.Mostly used in high-power inverter power supply and frequency conversion motor connection.
At present nonferrous metal spurt in prices ,copper conductor cost accountion for the cable more than 70% of the total cost of raw materials.In order to guarantee both meet the specification of copper conductor cable,and can significantly reduce the cost of cable.according to market demand .our company has used existing plant equipment. testing equipment,developed the copper clad aluminum composite conductor power cable.
 
Voltage:  0.6/1KV,1.8/3KV, 3.6/6KV ,35kV and below.
 
Standard :IEC 60502-2004
 
Product Named:
1.     The meaning of cable model in letter and number:
T....................................Copper conductor
L....................................Aluminum conductor
YJ..................................XLPE
V....................................PVC
Y....................................PE
 
Armor code:
2....................................Double steel tape armor
3....................................Thin steel wire armor
4....................................Thick steel wire armor
6....................................(Double)non-magnetic mental tape armor
7....................................Non-magnetic wire armor
 
Oversheath code:
2....................................PVC oversheath
3....................................PE oversheath
4....................................Elastomer oversheath
 
Using Festures of Power Cable:
1.Rated Voltage 0.6/1kV PVC Insulation Power Cable :
The long-term working temperature of cable conductor should be not more than 70°C.
 While short-circuit the highest working temperature of cable conductor should be not more than 160°C(5 seconds maximum duration);
The minimum bending radius for laying cable(D is diameter):single core unarmoured cable shoule be 20D,multi-core unarmoured cable shoule be 15D,single core armoured cable shoule be 15D,multi-core armoured cable should be 12D;
The environment temperature for laying cable should be not less than 0°C.
 
2. Rated Voltage 0.6/1kV XLPE Insulation Power Cable / Rated Voltage 3.6/6~26/35kV XLPE Insulation Power Cable :
The long-term working temperature of cable conductor should be not more than 90°C.
While short-circuit the highest working temperature of cable conductor should be not more than 250°C(5 seconds maximum duration);
 
3. Rated Voltage 0.6/1kV and Freqency Inverter Control System Power Cable :
Designed with fully symmetric space structure,cable has excellent electromagnetic compatibility;
Low and uniform positive sequence and zero-sequence impedances have greatly improved power quality compared with ordinary four-core cable;
The environment temperature for laying cable;PVC and XLPE insulation is 0°C;
The maximum working temperature of cable;PVC insulation is 70°C,XLPE insulation is 90°C;
Low-smoke halogen-free flame retardant cable:PH value of burning gas ≥4.3,conductivity≤10us/mm,minimum light transmittance shall not be less than 60% while product burning;
The minimum bending radius for laying cable is 12D(D is diameter).
 
4. Copper Clad Aluminum Power Cable
Maximum temperature of cable of cable conductors during normal operation and short-circuit (5 seconds maximum duration): PVC insulation is 70oC, the highest temperature should be not more than 160oC while short circuit; XLPE insulation is 90oC,the highest temperature should be not more than 250oC while short circuit;
The minimum bending radius for laying cable (D is diameter):single core unarmoured is 20D,three-core unarmoured is 15D, single core armoured is 15D,three-core armoured is 12D; 
The environmental remperature for laying cable should not less than 0oC
 
 
 
Product description
Rated Voltage 0.6/1kV XLPE Insulation Power Cable
TypeDescriptionApplication
CuAl
YJVYJLVCopper-core(aluminum core)XLPE insulation and PVC sheath power cableFor laying indoor,in tunnels and in ducts,unable to bear external mechanical forces
YJYYJLYCopper-core(aluminum core)XLPE insulation and PE sheath power cable
YJV22YJLV22Copper-core(aluminum core)XLPE insulation steel tape armoured PVC sheath power cableFor laying indoor,in tunnels and in ducts,can able to bear external mechanical forces
YJV23YJLV23Copper-core(aluminum core)XLPE insulation steel tape armoured PE sheath power cable
YJV32YJLV32Copper-core(aluminum core)XLPE insulation steel wire armoured PVC sheath power cableFor laying in water or ground along route with large difference of level,can able to bear external mechanical forces
YJV33YJLV33Copper-core(aluminum core)XLPE insulation steel wire armoured PE sheath power cable
YJV42YJLV42Copper-core(aluminum core)XLPE insulation thick wire armoured PVC sheath power cable
YJV43YJLV43Copper-core(aluminum core)XLPE insulation thick wire armoured PE sheath power cable
Notes:1.Ratproof,termite-proof,moisture-proof and other special requiremments cables are available.
            2.The single core armoured cable are used for DC system only.As for AC system,non-megnetical materials shoule be used,its corresponding code is 62,63,72,73;
            3.It is not recommended AL-core fire retardent cable.When there is a fire,flame temperatures may reach 700°C above due to the meilting point of aluminium is only 660°C,the conductor may be fused;
           4.Flame retaradant/fire resistant power cable are available:Representation method of flame retardant grade is the "Z" followed by"A","B","C",such as the "ZA","ZB","ZC".When "ZR" expressed,generally considered to be "C" class of flame retardant.Flame retardant level representation is "ZN" middle "A","B","C",such as the "ZA","ZB","ZC".While using "NH" expressed,it generally considered to be "ZCN".For example;
 
Rated Voltage 0.6/1kV PVC Insulation Power Cable :
TypeDescriptionApplication
CuAl
VVVLVCopper-core(aluminum core)PVC insulation and PVC sheath power cableFor laying indoor,in tunnels and in ducts,unable to bear external mechanical forces
VYVLYCopper-core(aluminum core)PVC insulation and PE sheath power cable
VV22VLV22Copper-core(aluminum core)PVC insulation steel tape armoured PVC sheath power cableFor laying indoor,in tunnels and in ducts,can able to bear external mechanical forces
VY23VLY23Copper-core(aluminum core)PVC insulation steel tape armoured PE sheath power cable
VV32VLV32Copper-core(aluminum core)PVC insulation steel wire armoured PVC sheath power cableFor laying in water or ground along route with large difference of level,can able to bear external mechanical forces
VY33VLY33Copper-core(aluminum core)PVC insulation steel wire armoured PE sheath power cable
VV42VLV42Copper-core(aluminum core)PVC insulation thick wire armoured PVC sheath power cable
VY43VLY43Copper-core(aluminum core)PVC insulation thick wire armoured PE sheath power cable
Notes:1.Flexible power cable is available.Plus "R" after sheath material types.For example,"VVR" refers to cooper core PVC insulation PVC sheath flexible power cable;
            2.Hear-resistant 90°C and 105°C power cable are available,Plus "-90" "-105" after the type.For example,VV-105 refers to copper core heat-resistant 105°C PVC insulation and sheath power cable,and the highest temperature of cable conductor is 105°C.
            3.Ratproof,termite-proof,moisture-proof and other special requiremments cables are available.
            4.The single core armoured cable are used for DC system only.As for AC system,non-megnetical materials shoule be used,its corresponding code is 62,63,72,73;
            5.It is not recommended AL-core fire retardent cable.When there is a fire,flame temperatures may reach 700°C above due to the meilting point of aluminium is only 660°C,the conductor may be fused;
            6.Flame retaradant/fire resistant power cable are available:Representation method of flame retardant grade is the "Z" followed by"A","B","C",such as the "ZA","ZB","ZC".When "ZR" expressed,generally considered to be "C" class of flame retardant.Flame retardant level representation is "ZN" middle "A","B","C",such as the "ZA","ZB","ZC".While using "NH" expressed,it generally considered to be "ZCN".For example;
 
 
 



About our company
Once shaking hands; always being friends.
 
                                        ---------------------------------------Harmonious relation with customers
 
 
Far East Cable Co., Ltd.,is the largest wire & cable manufacturing company in China, and sales revenue has ranked firstly in national wire & cable industry continuously for 18 years, its annual production and marketing ability exceeds 20 billion yuan, with global leading comprehensive strength.
 
Send your message to this supplier
Mr. Eric Li

Post a Sourcing Request Now

People who liked this also liked